Documentation / Integrations / Digital gages

I — Available interface

USB and Bluetooth keyboard-wedge gages

SVEND accepts numeric readings from digital gages and receivers that present themselves as a standard keyboard or Bluetooth HID device.

Status: Available · Gage R&R study bench

II — Input contract

Device behaviorSVEND behavior
Types a numeric measurementValidates and stages the value in the highlighted run-sheet row.
Sends Enter or TabCommits the staged cell and advances to the next unmeasured randomized run.
Sends invalid or decorated textHolds focus so the operator can correct or reject the input.
Has no machine-readable identityThe operator remains responsible for selecting and declaring the correct gage.

III — Setup

  1. Configure the device for keyboard or HID output: numeric value, then Enter.
  2. Confirm the operating-system keyboard layout produces the correct decimal separator and sign.
  3. Create and issue the Gage R&R plan. SVEND focuses the first unmeasured row.
  4. Transmit a known reference value and compare the gage display with the browser field.
  5. Run the study in the issued order and record the pending readings.
No SVEND driver is required. The browser receives the same keystrokes the device would send to a spreadsheet or text field.
Compatibility is not identity. Keyboard mode establishes that a value arrived without identifying the instrument that sent it. Use controlled stations and operator confirmation where traceable device identity is required.

IV — Documented examples

MobileCollect EVO keyboard output is available today. Sylvac Bluetooth HID matches this interface and is documented as interface-compatible with physical validation still pending.